Upgraded versions to Profile 3 for Windows
================================================================
Changes from 3.3.8 to 3.3.9
- Added some delay for RS232 communications to fix a problem when many
files are imported.
Changes from 3.3.7 to 3.3.8
- Changed some formulas.
Changes from 3.3.5 to 3.3.7
- "adj speed" renamed for less confusion, now labeled "OBDII Speed".
- "Veh speed" eliminated.
Changes from 3.3.4 to 3.3.5
- Added 3 new formulas on the Speed2 tab.
- Removed Gradient from all forms.
- Changed USB baud rate to work with many USB drivers.
- Fixed double click on *.run files to open into Profile.
Changes from 3.3.3 to 3.3.4
- Changed timing of RS232 communication so it works better with wireless
transmission.
Changes from 3.3.2 to 3.3.3
- Fixed problem with VC3000 Settings on the RFM tab, Operators. It
would not clear the operators properly.
Changes from 3.3.1 to 3.3.2
- Display average now exports with the average of runs data on the last
line instead of the first line.
- Font size increased on graph exports.
- Now when you save a graph, you have the option of saving as a BMP or a
metafile.
- Formulas: Now you can export the Math tables to HTML.
- Added user list to VC3000 Setup RFM tab.
Changes from 3.3.0 to 3.3.1
- Changed VC3000 USB communication to use the "Custom Baud Rate" property.
This negates the need for a custom (proprietary) Vericom device driver, so
the standard FTDI driver can be used.
- Formulas tables: added export to text.
- Data table: added export to text.
- Formulas lane change: added solve for speed.
Changes from 3.2.5 to 3.3.0
- Compiler update.
- Fixed Help button on some forms.
- New serial communications component.
- Support for future Gradient measurement.
- Run Data Form:
- Remove clear data command.
- Fix Barometric and Station pressure when switching between English and
Metric units.
- Added accelerometer zeroing status (VC3000 firmware 2.15+.
- Display Average:
- Added more display items
- Added checkbox for vehicle and time/date.
- Formulas:
- New formula images.Added new formulas.
- Added more expanded formulas.
- Better File history on the File menu.
- Uses Windows registry instead of INI file.
- Defaults to "My Documents" folder for .RUN files.
- VC3000 Setup
- Remove Settle time. It's automatic now.
- Fixed RFM operator name and airport name download problem.
- Added RFM average and peak modes. Note: Profile only supports the
RFM average mode for runway friction number calculations.
- Added default vehicle weight to Options.
- Graph: increased text size to 12 pts on graphic exports.
Changes from 3.2.4 to 3.2.5 1/28/2004
- Added Runway Friction Report.
- New serial communication component.
- Support for VC3000 larger header size, supports RFM parameters.
- Data Form: added Airport info tab.
- Import: if VC3000RFM then automatically create directory and import
all files into this directory. The RFM report then uses all files
in this directory to generate a report.
- Setup VC3000: added RFM parameters.
- Setup VC3000: new icon, and buttons bitmaps for Get and Set.
- Setup VC3000: configuration is based on VC3000 product ID.
- Compiler updated to latest version.
- No “New” under File or icon.
- Font on data tab changed to system.
- ASCII output from Display Average fixed.
- Formulas, math functions no longer
let user edit output results.
Changes from 3.2.3 to 3.2.4
- Added to the graphing sub-system an additional cursor selection. Cursor
selections now are: No cursor, single cursor that displays the value at the
cursor position, and the new average cursor modes. The average cursor
selection display two cursors, one green, the other red. The display shows
the average of the values between the two cursors. The green cursor is the
start of average, with the red cursor indicating the end. When in dual cursor
mode the keyboard left and right cursor keys will move the last selected
cursor.
- Fixed problem with Display Average, New parameters are not correctly
calculated when a run is deselected.
- VC3000 Setup fixed bug to display current host interface baud rate.Added "F1" key help context to many fields and forms.
- Display average, fixed scroll bar problem with file list
- Formulas, instead of loading forms at the start of profile. Created and
destroyed at execution time.
- Make Average, fixed the problem of not displaying Gx for brake runs.
- Graph, fixed problem with legend checkboxes not working when multiple runs
are displayed.
- Options, fixed problem when units are changed; default header information
units are not switched.
- Profile main, removed new run tool button.
- Added new pedal load cell to sensors.
- VC3000 Setup, Added user type and zeroing parameters.
- Formulas, protected (read only) result and table fields.Added HTML help compatibility.
- RUN files now associated with Profile so when a .RUN file is clicked on
in Windows explorer profile starts and opens the file.
- Zeroing added to the VC3000 setup dialog.
Changes from 3.2.2 to 3.2.3
- Added math for: distance for turn away, distance for lane change, and
minimum speed. These math routines use a graphical report writer for enhanced
printout.
- Added metric formulas.Changed formulas from radians to degrees. Accident reconstruction
personnel more commonly use degrees.
- Chart editor, fixed the editing of the chart grid.
- Display average, added check boxes, so operator can deselect runs from
averages.
- Sensor smoothing increased to 0-99 from 0-9.Data menu, added "save as ASCII".
- Updated charting software.
- Charting, added picture exports: PDF, Postscript, JPEG, GIF, PNG, PCX, and
VML.
- Charting, added save and restore of
graph parameters selections.
Changes from 3.2.1 to 3.2.2
- VC3000 Import has new feature to save runs in ASCII (*.csv) file format.
Excel may be used to read these files.
- Move the default run parameters from the Import form to the options form.
Added to Options form Header Defaults, Sensor Defaults, and OBDII Defaults.
These default parameters are written to the Profile.INI file.
- OBDII Distance added. OBDII Distance is calculated from OBDII Speed.
- OBDII distance calibration parameters added.
- Smoothing for analog sensors and OBDII sensors added.
- Data run header changed for OBDII Distance parameters and smoothing
parameters.
- Fixed bug in Save-As-ASCII and Save-as-Text. Was not writing new
parameters.
- Added Reaction Time in Display Average.
- Added Reaction Time in Quick Stats for brake runs.
- Added Reaction Time in Quick Stats for acceleration runs.
- Added End Stats tab for acceleration runs.
- Added Print button on formulas form.
- Added OBDII Distance to meters form.
- Added factory default setup information.
Changes from 3.2.0 to 3.2.1
- Graph for VC2000 run overlays fixed.
Lateral G not opened. Only affected VC2000 runs.
Changes from 3.1.7 to 3.2.0
- OBDII parameters supported.
- Automatic COM port search and automatic Baud Rate.
- Multiple graphs and meters can now be opened.
- Close confirmation box when closing Program.
- Data Print does not print extra header info on brake
runs.
- Quick Stats for Brake runs shows only 3 digits after
decimal.
- Various minor bug
fixes.
Changes from 3.1.6 to 3.1.7
- Display Average for acceleration runs; HP
SL fixed.
- HP, RPM, Torque and acceleration in dsp.
Avg. use average, not instant.
- Decimal places on New Parameters in dsp.
Avg. use 2, not 1.
- Average G line in graph.
- Time added to display average, in the
date column.
Changes from 3.1.5 to 3.1.6
- Stats for acceleration runs
finds maximum speed for options instead of end speed.
- Quick Stats acceleration has 3
digits, not 4 after decimal point.
- Bug fixed from 3.1.3:
Profile.ini grows huge if quick stats for acceleration runs is used.
- Bug fixed: Printing more than 31 runs in
display average would crash.
- Up to 10 new parameters can be added to
brake runs.
- Known issue: In Display Average for acceleration runs,
HP SL not correct.
Changes from 3.1.4 to 3.1.5
- Stats for acceleration runs finds
maximum speed for options instead of end speed.
Changes from 3.1.3 to 3.1.4
- Fixed error on VC3000 Settings tab when switching between Metric and
English.
- Help has Vericom's current address.
Changes from 3.1.2 to 3.1.3
- Sensor range chosen from 4 fields, Volts high and low,
Units high and low.
- The conversion from In. HG to Bar is corrected for
pressure.
- Bar now reads mBar.
- No saving as ASCII under the file menu Save As…
- Factory sensors to choose from.
- 3 new formulas on Radius tab.
- Updated Help.
Changes from 3.1.1 to 3.1.2
1. Added
4 fields for VC3000 bar graph range and alarm thresholds.
2. New address in About.
3. Clickable web address and email address in About box.
4. Minor other changes.
Changes from 3.1.0 to 3.1.1
1. Sensors that have been calibrated now range correctly.
2. Display average opens the Open dialog first, and can select many runs at
once, including saved ASCII files.
3. Zero adjust checkbox for sensors on the VC3000 Settings tab now works.
Changes from 3.0.0 to 3.1.0
1. Added second tachometer.
2. Fixed Metric problems with Quick Stats.
3. Fixed bug - Tach1 checkbox never set in run window VC3000 Settings tab.
4. Changed metric maximum barometric and station pressure from
889 to 1200.
5. Minor other fixes.
Changes from 2.x to 3.0
1. For the VC3000 only.
2. New Graphing.
3. New Meters.
4. New importing method. All user commands are done from Profile so the VC3000 only needs to be turned on and connected to import data.
5. USB functionality added.
6. Various new panels added for VC3000 interface.
7. Profile can be used to set the VC3000 setup.
8. Many other enhancements.
Changes from 2.0.16 to 2.5.0
- New Graphing.
- New Meters.
- New importing to make importing multiple runs more reliable.
- Misc. error fixes.